energie.design lab

As a result of several years of research work by the ai:L in the field of facade development and building physics, the institute has laboratory and measuring technology at its disposal with which various types of building climate measured values can be determined locally. These include U-values of building components, room temperatures and humidity, air tightness, sound levels, luminance and global radiation. In addition, we have access to a CNC milling machine and a 3D printer with which models and prototypes of all kinds can be produced.

The measurement technology at a glance:

Infrared camera Flir E6, Ex-Series

The IR camera detects temperature differences < 0.06 °C. This is an advantage for building inspections and moisture investigations in building components, where thermal temperature differences are often minimal.

Infrarotkamera Flir E6, Ex-Serie

Die IR-Kamera erkennt Temperaturunterschiede < 0,06 °C. Ein Vorteil bei Gebäudeinspektionen und Feuchtigkeitsuntersuchungen in Bauteilen, bei denen die thermischen Temperaturunterschiede oft minimal sind.

Data Logger Ahlborn 2890-9

The universal data logger has a total of 9 measuring inputs and an internal measured value memory as well as an external storage option for an SD card. In addition, it has 2 outputs for USB, RS232, Ethernet and analogue.
 

Datenlogger Ahlborn 2890-9

Der Universaldatenlogger hat insgesamt 9 Messeingänge und einen internen Messwertspeicher sowie eine externe Speichermöglichkeit für eine SD-Karte. Zusätzlich besitzt er 2 Ausgänge für USB, RS232, Ethernet und Analog.

Data Logger Ahlborn 2590-2

The universal data logger has two measuring inputs, an internal measured value memory and an external storage option (SD card). It has outputs for USB, RS232, Ethernet and analog and is suitable for applications with a handheld device.

Datenlogger Ahlborn 2590-2

Der Universaldatenlogger hat zwei Messeingänge, einen internen Messwertspeicher sowie eine externe Speichermöglichkeit. Er besitzt Ausgänge für USB, RS232, Ethernet und Analog und ist für Anwendungen mit einem Handgerät geeignet.

Sound level meter Ahlborn MA86193

The measuring range of the digital sound level meter is between 35 and 130 dB with an accuracy of ± 2.0 dB. The frequency weighting can be output in A and C. For recording the measured values, the meter can be connected to all ALMEMO devices.

 

Schallpegelmesser Ahlb. MA86193

Der Messbereich des digitalen Schallpegelmessers liegt zwischen 35 und 130 dB bei einer Genauigkeit von ± 2,0 dB. Die Frequenzbewertung kann in A und C ausgegeben werden. Zur Messwertaufzeichnung kann das Messgerät an alle ALMEMO-Geräte angeschlossen werden.

Measuring module: Humidity & Temperature Ahlb. FHAD460 L10

The module enables the digital transmission of measured values from the sensor element to the measuring instrument to avoid errors due to digital-to-analog conversion in the sensor or analog-to-digital conversion in the measuring instrument.

Messmodul Feuchte & Temperatur Ahlborn FHAD460 L10

Das Modul ermöglicht die digitale Übertragung von Messwerten vom Sensorelement an das Messgerät, um Fehler durch Digital-Analog-Wandlung im Sensor bzw. Analog-Digital-Wandlung im Messgerät zu vermeiden.

Measuring module: Humidity & Temperature Ahlb. FHAD462

The module enables the digital transmission of measured values from the sensor element to the measuring instrument to avoid errors due to digital-to-analog conversion in the sensor or analog-to-digital conversion in the measuring instrument.

Messmodul Feuchte & Temperatur Ahlborn FHAD462

Das Modul ermöglicht die digitale Übertragung von Messwerten vom Sensorelement an das Messgerät, um Fehler durch Digital-Analog-Wandlung im Sensor bzw. Analog-Digital-Wandlung im Messgerät zu vermeiden.

Illuminance measuring head Ahlborn FLA613VL

The measuring head determines the existing area-related luminous flux with the aid of two measuring channels for interior lighting (light-sensitive) and for ambient light (less light-sensitive).
 

Beleuchtungsstärke-Messkopf Ahlborn FLA613VL

Der Messkopf ermittelt den vorhandenen flächenbezogenen Lichtstrom mithilfe zweier Messkanäle für Innenbeleuchtung (lichtempfindlich) bzw. für Umgebungslicht (lichtunempfindlicher).

Global radiation measuring head Ahlborn FLA613VLM

The measuring head determines the current incoming solar radiation and is particularly suitable for outdoor measurements, e.g. for climate research, in weather information and forecast systems.
 

Globalstrahlungs-Messkopf Ahlborn FLA613VLM

Der Messkopf ermittelt die aktuell eintreffende Solarstrahlung und ist besonders für Messungen im Außenbereich geeignet, z. B. für die Klimaforschung, in Wetterinformations- und Prognosesystemen.

Luminance measuring head Ahlborn FLA603LDM2

The measuring head is equipped with an achromatically corrected, low-scattered light optics and a high-quality V-detector according to DIN class B. The external sighting device enables an exact location of the measuring point.

Leuchtdichte-Messkopf Ahlborn FLA603LDM2

Der Messkopf ist mit einer achromatisch korrigierten, streulichtarmen Optik und einem hochwertigen V-Detektor nach DIN Klasse B ausgestattet. Die äußere Visiereinrichtung ermöglicht dabei eine exakte Anpeilung des Messortes.

Meteo multi sensor Ahlborn FMA-510

This tool is a measuring system for determining the important weather parameters temperature, relative humidity, air pressure, wind speed, wind direction and liquid precipitation.
 

Meteo-Multigeber Ahlborn FMA-510

Der Multigeber ist ein kompaktes Multisensor-Messsystem zur Ermittlung der wichtigen Wetterkenngrößen Temperatur, relative Luftfeuchte, Luftdruck, Windgeschwindigkeit, Windrichtung und flüssiger Niederschlag.

Thermoelectric flow sensor Ahlborn FV A605 TA

The sensor is suitable for detecting low flow velocities in gaseous media. Typical applications are measurements for comfort as well as in air conditioning and ventilation technology.

Thermoelektr. Strömungssensor Ahlborn FV A605 TA

Der Sensor ist zur Erfassung kleiner Strömumgsgeschwindigkeiten in gasförmigen Medien geeignet. Typische Anwendungsbereiche sind Messungen zur Behaglichkeit sowie in der Klima- und Lüftungstechnik.

Barometer Greisinger GMH3161-12

The barometer measures pressures from 0 - 1300 mbar, the resolution is 1 mbar. Its accuracy is ± 0.4 % FS (0 - 50° C). The measuring pressure can be output in the units mbar, bar, kPa, MPa, PSI, mmHg.
 

Barometer Greisinger GMH3161-12

Das Barometer misst Drücke von
0 - 1300 mbar, die Auflösung beträgt 1 mbar. Seine Genauigkeit liegt dabei bei ± 0,4 % FS (0 - 50° C). Der Messdruck kann in den Einheiten mbar, bar, kPa, MPa, PSI, mmHg ausgegeben werden.